  • P5010 multistage ejector with Pi, Si or Xi COAX® push-in cartridge(s).
  • AVM™2, Automatic Vacuum Management, unit with built-in control and monitoring functions.
  • Valves for vacuum on/off, blow-off, blow-off flow control and non-return valve.
  • Option with Normally Closed "fail safe" on/off valve (NC). It changes to an open valve if power is lost and vacuum will be generated. A conventional normally closed on/off valve (NC 2) is also available. It stays closed if electrical power is lost or removed.
  • Option with automatic blow-off (1 sec) reduces number of outputs needed from PLC or I/O box.
  • Enhanced blow-off effect thanks to a directed blow-off pipe.
  • Analogue vacuum sensor with two digital outputs, 16 pre-set combinations of signal levels to choose from.
  • Digital display with “-kPa” or “-inHg” as unit options.
  • Integrated energy saving function (ES) that minimizes the air consumption in sealed systems. The ES function can be activated manually or via a signal (signal override).
  • Three-colour LED status indicators for valves, signal outputs and ES.

Packaging

  • Direct food contact
  • Rotary carton feeding

General

Material
Al , CuZn , Nitrile (NBR) , PA , PE , PMMA , SS
Noise level
68 - 71 dBA
Temperature
0 - 50 °C
Weight
430 - 720 g

Electrical data

Current, consumption (nominal.)
110 mA
Current, output (max. output load.)
40 mA
Display
LED indicators, numeric
Ripple, max.
1 V_rms
Safety classification
IP65 [NEMA 4]
Supply voltage
22 - 28 VDC
Supply voltage, nominal
24 VDC

Performance

Feed pressure, max.
0.7 MPa

Pneumatic data

Vacuum flow, range (Blow-off.)
0 - 7.5 Nl/s

Signal function

Hysteresis
7±1 kPa
Signal range
20 - 80 -kPa
Feed pressureAir consumptionVacuum flow (Nl/s) at different vacuum levels (-kPa)Max vacuum
MPaNl/s0102030405060708090-kPa
0.62.3300000000000
0.63.5500000000000
0.61.753.332.61.70.90.60.50.350075
0.451.832.82.31.610.730.580.430.320.180.0395
0.312.055.62.51.81.10.650.50.350.250.1090
0.61.7563.52.61.70.90.60.50.350075
0.322.82.51.81.10.650.50.350.250.1090
0.63.500000000000
0.62.3300000000000
0.451.835.9321.30.730.580.430.320.180.0395